WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully read. PC1616/PC1832/PC1864 User Manual v4.5 and higher. Jan 05, 2017 DSC PowerSeries PK5500 Alarm Keypad. Make sure this fits by entering your model number. DSC PK5500 Frequently bought together + + Total price: $223.08. Add all three to Cart Add all three to List. 6300 USER MANUAL. Seller Videos. Videos for related products. PC1616/PC1832/PC1864 User Manual. FCC COMPLIANCE STATEMENT. Alarm dialing equipment must be able to seize the telephone line and place a call in an emer. PK5500/PK5501 Status Lights Number Pad Emergency Keys Zone Lights PC1555RKZ LCD5511 Display System Lights Number Pad LED5511.
Advertising
UL Listed Commercial and Residential Installations
The installation requirements listed below must be met for the following
grades of service. Grade AA Central Station and Police Connect (Standard or Encrypted Line Security Service) The installation must use T-Link module which communicates over LAN/WAN to the Sur-Gard MLR-IP receiver or the TL200/250 which communicates over LAN/ WAN/Internet to the SG System III receiver. Polling time must be 90 seconds. Com- promise detection time must be 6 minutes. Grade A Local •The installation must have a bell which is UL Listed for mercantile local alarms
(AMSECO MBL10B with model AB-12 bell housing).
•The digital communicator must be enabled.
•The control panel must be in the attack-resistant enclosure (DSC Model CMC-1
or PC4050CAR).
Grade B Central Station and Police Connect
•The installation must have a bell which is UL Listed for mercantile local alarms
(AMSECO MBL10B with model AB-12 bell housing). Night time app for mac.
•The digital communicator must be enabled.
•The control panel must be in the attack resistant enclosure (DSC Model CMC-1
or PC4050CAR).
Dsc Rfk5500 User Manual
Grade C Central Station
•The digital communicator must be enabled. •The control panel must be in the attack resistant enclosure (DSC Model CMC-1
or PC4050CAR).
All Commercial Installations
•The Entry Delay must not exceed 120 seconds •The Exit Delay must not exceed 120 seconds. •The minimum Bell Time-out is 15 minutes. Residential Fire & Burglary Installations •The Entry Delay must not exceed 45 seconds •The Exit Delay must not exceed 60 seconds. •The minimum Bell Time-out is 4 minutes. Home Health Care Signaling Equipment •There must be at least two keypads, one of either the LCD5500Z/LCD5520Z or
LCD5501Z and one of the following models, PC5508Z, PC5516Z or PC5532Z.
•Each system shall be programmed to activate an audible Trouble signal within 90
seconds upon loss of microprocessor memory.
•The minimum Bell Time-out is 5 minutes.
Programming The notes in the programming sections describing the system configurations for UL Listed installations must be implemented. Control of the Protected Premises In order to have a UL Certificated system the protected area is to be under the responsibility of one ownership and management (i.e., one business under one name). This may be a group of buildings attached or unattached with different addresses but under the responsibility of someone having mutual interest. The person of mutual interest is not the alarm-installing company. Bell Location The alarm sounding device (bell) must be located where it can be heard by the person or persons responsible for maintaining the security system during the daily arming cycle. Protection of the Control Unit The local control and the local power supply must be protected in one of the fol- lowing ways: •The control unit and audible alarm device must be in a protected area which is
armed 24 hours a day.
•Each partition must arm the area protecting the control unit and the audible
alarm device power supply. This may require duplicate protection armed by each
partition. Access to this protected area, without causing an alarm, will require that all partitions be disarmed.
•In all cases described above, the protected area for the control unit must be pro-
grammed as not-bypassable.
Casual Users
The installer should caution the user(s) not to give system information to casual users (e.g. codes, bypass methods, etc. to baby-sitters or service people). Only the One-Time Use codes should be given to casual users.
User Information
The installer should advise the users and note in the User’s Manual: •Service organization name and telephone number •The programmed exit time •The programmed entry time •Test system weekly Two-Wire Smoke Detector Compatibility (if available) Maximum loop resistance: 24 Ohms •Operating Voltage Range: 9.8 - 13.8 V
DC
•Maximum Alarm Current: 89 mA
•Compatibility Identifier: PC18-1 See Section 5PGM Wiring for compatible 2-wire smoke detectors.
SIA FAR Installations
Minimum requirement system for SIA-FAR Installations:
• 1 PC1616/PC1832/PC1864 Control panel
• 2 Local annunciation devices
The local annunciation devices may be any combination of the following keypads,
as long as there is at least one LCD keypad in the installation (Model LCD5500Z or PK5500).
• LCD5500Z
• LCD5501Z
• PK5500
• PK5508
• PKP-LCD
• PKP-ICN
• PK5501
• PK5516
The following optional subassembly modules also bear the SIA FAR classification
and may be used if desired:
PC5108 Zone Expander Module
Compatible initiating devices: Bravo200 series, 300 series, 400 series, 500 series, 600 series, AC-100, Encore300 series, Force200 series, 210 series, MN240.
PC5208 Low Current PGM Output Module
The following optional accessory modules also bear the SIA FAR classification and may be used if desired. PC5204 Auxiliary Power Supply with PGM output ports Escort5580/Escort5580TC, PC5400 Printer Module
Caution Schiller argus pro lifecare 2 user manual.
• For SIA FAR installations, only use modules / devices that are listed on this page.
• Fire Alarm Verification feature (Auto Verified Fire zone) is not supported on 2-
wire smoke detectors zones. This feature may be enabled for 4-wire smoke
detectors only.
• Call Waiting Cancel (Section 382 Option 4) feature on a non-Call Waiting line
will prevent successful communication to the central station.
• All smoke detectors on the system must be tested annually by conducting the
Installer Walk Test prior to exiting the walk test mode, a sensor reset must be
conducted on the system, [
✱][7][2] to reset all latching 4-wire smoke detectors.
Please refer to the smoke detector installation instructions on how to correctly
test the detectors.
Notes
• Programming at installation may be subordinate to other UL requirements for
the intended application.
• Cross zones have the ability to individually protect the intended area (e.g.,
Music tag editor download mac. motion detectors, which overlap).
• Cross zoning is not recommended for line security Installations nor is it to be
implemented on exit / entry zones.
• There is a communication delay of 30 seconds in this control panel. It can be
removed, or it can be increased up to 45 seconds at the option of the end user
by consulting with the Installer.
• Do not duplicate any reporting codes. This applies for all communication for- https://clevercv129.weebly.com/blog/download-syslog-server-mac-free.
mats other than SIA sending automatic programmed reporting codes.
• The control unit must be installed with a local sounding device and an off-
premise transmission for SIA communication format.
• For ULC Listed Fire Monitoring Installations & module requirements, please refer
to the ULC Installation Information sheet, part# 29002157.
Dsc Pk5500 User Guide
• Use a CSA/cUL transformer, hardwired.
• All tamper circuits may be connected to the same zone. • Use ULC-LA for AC Power indication.
LISTING REQUIREMENTS
Advertising
This manual is related to the following products:
Popular Brands
Popular manuals
Causes and Solutions
If your DSC home alarm is beeping every 10 seconds or so, there could be many possible causes. In most cases, it’s because the alarm panel has detected one or more “trouble” conditions. These include things like low battery trouble, phone line failure, and communication problems, among many others.
Note: DSC keypads also emit 'normal' beeping caused by the 'Chime' function. You can easily toggle this on or off by pressing and holding the 'Chime' button on any keypad that has function keys. For keypads without a chime button, just press '*4'.
On this page, I’ll show you how to silence trouble beeping, and how to use a few easy keypad commands to find the source of the trouble. I’ll also explain how to fix some of the most common causes of alarm system beeping.
If you have a brand of alarm panel other than DSC, see 'My Alarm Keeps Beeping - What Can I Do?'.
While beeping alarm keypads can be very annoying, they’re designed that way for a reason. The alarm beep is intended to get your attention so you’ll go to the keypad, where you can then get a detailed visual indication of what the problem is. Unfortunately, these problems usually seem to crop up in the middle of the night! How to Silence the Beeping Keypads1) Go to any keypad and make sure the system is disarmed. If not, enter your disarm code as usual. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |